Soldering Iron Thermometer HS series

画像
画像

Model HS series thermometers designed for exclusive use with the CR series soldering iron tip temperature probes.
The HS-30K measures temperatures only, while the HS-50K can measure temperature,
resistance between soldering iron tip and ground, and leakage voltage.


HS-30K

画像

Measurement range: 0 to 500°C
Power supply: 4AA(LR6) Alkali Batteries
(Temperature probe sold separately.)
* Unrepairable

Download catalog

Specifications HS-30K

Model

HS-30K

Display

LCD

Input type

Temperature
(Thermocouple : Type K)

Measurement range

0 to 500°C

Resolution

1°C

Measurement accuracy

± (0.3% of reading + 1)°C

Reference junction
compensation accuracy

±0.5°C (at 23°C±10°C)

Temperature coefficient

± (0.03%/°C) of measurement
range except 23°C±10°C

Environmental limit

Operation

10 to 40°C,0 to 85%RH (without dew)

Storage

0 to 50°C,0 to 85%RH (without dew)

Linearlizer

Analog linearlizer method
(Compliant with IEC 60584-1(2013))

Power supply

4AA(LR6) Alkali Batteries

Battery Life

approx. 180h

Dimensions

152(W)*45(H)*50(D) mm

Weight

approx. 460g

Accessories

Manual, 4 Batteries, Test report

 

 

 

HS-50K

画像

Measurement range: 0 to 500°C
Power supply:AC 100V to 240V
(Temperature probe sold separately.)

Download catalog

Specifications HS-50K

Model

HS-50K

Display

LED

Input type

Temperature (Thermocouple : Type K)
Resistance (between the iron ahead ground)
leak electric voltage

Measurement range

Temperature : 0 to 500°C
Resistance (between the iron ahead ground) : 0.0 to 99.9 Ω
leak electric voltage : 0.0 to 99.9mV (RMS)

Resolution

Temperature : 1°C
Resistance (between the iron ahead ground) : 0.1 Ω
leak electric voltage : 0.1mV

Measurement accuracy

Temperature : ± (0.3% of reading + 1)°C
Resistance (between the iron ahead ground) : ± (4% of reading 0.3)Ω
leak electric voltage : ± (3% of reading +0.3)mV

Reference junction
compensation accuracy

±0.2°C (at 23°C±10°C)

Temperature coefficient

± (0.01%/°C) of measurement
range except 25°C±10°C

Environmental limit

Operation

10 to 40°C,0 to 85%RH (without dew)

Storage

-20 to 40°C,0 to 85%RH (without dew)

Linearlizer

Digital linearlizer method
(Compliant with IEC 60584-1(2013))

Power supply

AC 100V to 240V

Dimensions

180(W)*55(H)*150(D) mm

Weight

approx. 950g

Accessories

Manual, Spare fuse, Power supply cord, Ground cord, Test report

About repair

HS-50K is available for repair. Please ask our dealer.


Exclusive probes CR series

CR-31K

画像

Thermocouple type: Type K
Max. temp.: 500°C
Tolerance: ±4°C(at 300°C)
Diameter supporting iron future: Less than φ1.5mm
* Unrepairable
* Details of CR series
(In the case of HS-30K or HS-50K, please select the type K)

CS-32K

画像

Thermocouple type: Type K
Max. temp.: 500°C
Tolerance: ±4°C(at 300°C)
Diameter supporting iron future: φ1.5mm to φ4mm
* Unrepairable
* Details of CR series
(In the case of HS-30K or HS-50K, please select the type K)