Handheld Thermometer HD-1202E / 1202K

ハンディタイプ温度計HD-1202E / 1202K

Measurement Range:E -200 to 800°C / K -200 to 1370°C

ホールド
HOLD
The thermometer stops measurement
by the HOLD key and holds the present readings.
オートパワーオフ
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
分解能切替
Resolution change
Press the 1/0.1 key to change the resolution of readings.
PVホールド
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
バックライト
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Analog output type
10mV/°C

(Temperature probes not included)

Download catalog

Specifications

ModelHD-1202
DisplayLCD with Backlight
Waterproof specifications-
Input connectorASP
Input typeThermocouple Input: Type E, K
Channel1ch
Signal source resistanceMAX.500ohm
Measurement Range1°C ResolutionE-200 to 800°C
K-200 to 1370°C
0.1°C ResolutionE

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

K

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

Measurement Accuracy1°C Resolution0°C to± (0.1% of reading +1°C)
to 0°C± (0.5% of reading +1°C)
0.1°C Resolution0°C to± (0.05% of reading + 0.2°C)
to 0°C±0.5°C
Reference junction compensation accuracy±0.2°C at 25°C±10°C
Temperature Coefficient±0.01% of F/S per °C (F/S : full scale)
Operation Environment

0 to 40°C, 0 to 80%RH (Non condensing)

32 to 104°F, 0 to 80%RH (Non condensing)

Storage Environment

-20 to 50°C, 0 to 85%RH (Non condensing)

-4 to 122°F, 0 to 85%RH (Non condensing)

Battery life150h
Power supply(Dry battery)4 AA Alkali Batteries
Power supply(AC power)AC-Adaptor (Option)
Sampling rateapprox.300ms
LinearlizerDigital Linearizer method (Compliant with IEC 60584-1 (2013))
Dimensions(mm)approx. 76(w)×167(H)×36(D)  [Protruded parts excluded]
Weightapprox. 350g [Include Batteries]
Supplied accessoriesManual,Test report,Soft case,
Hand strap,4 AA Alkaline batteries
Optional accessoriesAnalog output Cable
Alarm Output-
Analog Output10mV/°C (Table1)
Compatible standardsCE Marking, RoHS


Table1 Analog Output (Resistance:100ohm)(Range:All range at 0.1°C resolution)

 Accuracy
25°C±5°C±0.15% of F/S+1mV
except 25°C±5°C±((0.15% of F/S+1mV)+(±0.01% of F/S))

 

Supplied accessories

試験成績書

Test report

ソフトケース 形名:SCHD

Soft case model:SCHD

ハンドストラップ

Hand strap

アナログ出力

Analog output Cable
model:ANGHA-1.5

Optional accessories

画像

AC-Adaptor

model : A-115-500-HR-R (for AC115V)
model : A-220-500-HR-R (for AC220V)
for HD-1201,HD-1202,HD-1251,HD-1252,HD-1300,HD-1350,HD-1301,HD-1351,HD-1302,HD-1352,HD-1500,HD-1550
* Not CE-approval

About repair

This product is available for repair. Please ask our dealer.