Measurement Range
E -200 to 800°C / K -200 to 1370°C
Channel
6ch (ANP connector (same type thermocouple))
Input Type
Thermocouple Input : Type E, K (typeJ,T,R(option))
Voltage input
Interface
USB2.0(microーB)
Interval
(The following numbers are time of interval that can be set.) 
less than 1s : 0.1s ~ 0.99s Over 1s :  1s ~ 99m 59s 
(Temperature probes not included)
| Model | AM-9000 | 
| Number of inputs | 6ch : ANP connector (Miniature Plug) | 
| Input connector | ANP connector (same type thermocouple) | 
| Input type | Temperature: E, K, J, T, R by selected model *2 DC Voltage:V  | 
| Measurement range | Temperature: TABLE Ⅰ DC Voltage : ±20.000V | 
| Resolution | Temperature: 0.1℃/1℃ DC Voltage : 0.001V | 
| Measurement accuracy | Temperature: TABLE Ⅱ DC Voltage : ±(0.05% of reading +0.003V) | 
| Memory capacity | 120,000 data | 
| Interface | USB2.0 (micro-B) | 
Dimensions  | 92(W)×155(H)×36(D) | 
| Weight(Including dry batteries) | approx.380g | 
| Reference junction compensation accuracy  | ±0.3℃*3 | 
| Temperature coefficient | ± (0.04 × Δt ℃) *4 | 
| Time interval | 0.1 second to 99 minutes 59 seconds  | 
| Signal source resistance | 500Ω or less (measurement interval 1 second or more)/100Ω or less (measurement interval less than 1 second) | 
| Safe excitation voltage | Between input pins on same channels :±30VDC,Between input pins on adjacent channels : 150Vp-p | 
| Linearlizer | Digital Linealizer method (Compliant with JIS C1602-2015) | 
| Display | Graphic liquid crystal display, 128×64 dots | 
| Environment operational Environment storage  | Operation : 0〜40℃、15〜80%RH (Non condensing)    | 
| Battery life | TABLE Ⅲ | 
| Power supply | 4 AA Alkaline batteries(Supplied accessories) or AC-Adaptor(Optional accessories) | 
| Supplied accessories | Manual, Test report, Softcase, Communications cable, 4 AA Alkaline batteries | 
| Optional accessories | Special data analysis software, AC-Adaptor, Carrying case | 
| Compatible standards | CE Marking, RoHS2 | 
The selected thermocouple type (E・K・J・T・R) is entered in ※ of the model name.
*1 Thermocouple type (E・K・J・T・R)
*2 Type J・T・R are optional
*3 At 25℃±10℃
*4 When the ambient temperature is other than from 15℃ to 35℃, "the excess temperature from the ambient temperature Δt℃" x 0.04 is added to the measurement accuracy.
 
| Thermocouple type | Measurement range | 
| E | -200 to 800°C | 
| K | -200 to 1370°C | 
| J | -200 to 1100°C | 
| T | -200 to 400°C | 
| R | 0 to 1760°C | 
In the environment of 25 ℃ ± 10 ℃, when the measurement interval is 1 second or more without including the reference junction compensation accuracy.
| Thermocouple type | Accuracy compensation range | Measurement accuracy | 
| E,K,J,T | -200.0~-100.1℃ | ±1.0℃ | 
| -100.0~-0.1℃ | ±0.5℃ | |
| 0.0~200.0℃ | ±0.3℃ | |
| 200.1~500.0℃ | ±0.5℃ | |
| 500.1℃or more | ±0.7℃ | |
| R | 0.0℃~500.0℃ | ±1.5℃ | 
| 500.1℃or more | ±2.0℃ | 
*If the measurement interval is less than 1 sec, add ± 0.5 ℃ at type E ・ K ・ J ・ T and add ± 1.0℃ at type R
| Setting interval | 0.2sec | 1sec | 10sec | 
| AM-9000 Series | approx. 50 hours | approx. 55 hours | approx. 140 hours | 
If the number of used channels is less than 12, the usable time will be longer.
                AD-115-500-HR-R (for AC115V)
AD-220-500-HR-R (for AC220V)
                AM-CC2
This product is available for repair. Please ask our dealer.