Compact Thermologger AM-9000 series

List of specifications

ModelAM-9000※AM-9100※AM-9200AM-9300
Channel6CH12CH6CH12CH
Input connectorANP connector (same type thermocouple)ANP connector (both poles are coper)
Input typeTemperature: E, K, J, T, R by selected model *2Temperature:Multi-input (E・K・J・T・R)
DC Voltage:VDC Voltage:V
Measurement rangeTemperature: TABLE Ⅰ
DC Voltage : ±20.000V
ResolutionTemperature: 0.1℃/1℃
DC Voltage : 0.001V
Measurement accuracyTemperature: TABLE Ⅱ
DC Voltage : ±(0.05% of reading +0.003V)
Memory capacity120,000 data
InterfaceUSB2.0(microーB)
Dimensions92×155×3696 ×160 ×6092×155×3696 ×160×60
(W)×(H)×(D)mm *Protruded parts excluded
Weight(Including dry batteries)approx.380gapprox.480gapprox.410gapprox.540g
Reference junction
compensation accuracy
±0.3℃*3±0.5℃*3
Temperature coefficient±(0.04×Δt℃)*4
Time intervalless than 1s : 0.1s ~ 0.99sless than 1s : 0.2s ~ 0.99sless than 1s : 0.2s ~ 0.99s
Over 1s : 1s ~ 99m 59sOver 1s : 1s ~ 99m 59sOver 1s : 1s ~ 99m 59s
Signal source resistance500Ω or less (measurement interval 1 second or more)/100Ω or less (measurement interval less than 1 second)
Safe excitation voltageBetween input pins on same channels :±30VDC
Between input pins on adjacent channels : 150Vp-p
LinearlizerDigital Linealizer method (Compliant with JIS C1602-2015)
DisplayGraphic liquid crystal display, 128×64 dots
Environment operational
Environment storage
Operation : 0〜40℃、15〜80%RH (Non condensing)  
Storage : -10〜50℃、10〜85%RH (Non condensing)
Power supply4 AA Alkaline batteries(Supplied accessories) or AC-Adaptor(Optional accessories)
Supplied accessoriesManual, Test report, Softcase, Communications cable, 4 AA Alkaline batteries
Optional accessoriesSpecial data analysis software, AC-Adaptor, Carrying case
Compatible standardsCE Marking, RoHS2

The selected thermocouple type (E・K・J・T・R) is entered in ※ of the model name.
*1 Thermocouple type (E・K・J・T・R)
*2 Type J・T・R are optional
*3 At 25℃±10℃
*4 When the ambient temperature is other than from 15℃ to 35℃, "the excess temperature from the ambient temperature Δt℃" x 0.04 is added to the measurement accuracy.

TABLE Ⅰ : Measurement Range

Thermocouple typeMeasurement range
E-200 to 800°C
K-200 to 1370°C
J-200 to 1100°C
T-200 to 400°C
R0 to 1760°C

TABLE Ⅱ : Measurement accuracy

Thermocouple typeAccuracy compensation rangeMeasurement accuracy
AM-9000※/AM-9100※AM-9200/AM-9300
E,K,J,T-200.0~-100.1℃±1.0℃±1.5℃
-100.0~-0.1℃±0.5℃±1.0℃
0.0~200.0℃±0.3℃±0.5℃
200.1~500.0℃±0.5℃±0.7℃
500.1℃以上±0.7℃±1.0℃
R0.0℃~500.0℃±1.5℃±2.0℃
500.1℃以上±2.0℃±2.5℃

*If the measurement interval is less than 1 sec, add ± 0.5 ℃ at type E ・ K ・ J ・ T and add ± 1.0℃ at type R

TABLEⅢ 12ch model standard time for continuous use (at 25 ℃, using alkaline AA batteries)

Setting interval0.2sec1sec10sec
AM-9000 Seriesapprox. 50 hoursapprox. 55 hoursapprox. 140 hours

* If the number of used channels is less than 12, the usable time will be longer.